{"product_id":"tsh-005a-12-24-48v-testbench","title":"TSH-005A 12,24 \u0026 48V Testbench","description":"\u003cp\u003e\u003cstrong\u003eTSH-005A\u003c\/strong\u003e is the optimal solution for comprehensive diagnostics of alternators and starters. The test bench combines high measurement accuracy, convenient operation, and support for modern technologies, making it an effective tool for service centers and workshops of any level.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Alternators 12 V and 24 V with any type of connection.\u003cbr\u003e• Stop-Start system alternators (12 V) – with the ability to diagnose in both alternator and starter modes.\u003cbr\u003e• I-ELOOP alternators (Mazda).\u003cbr\u003e• 48 V belt starter-generators controlled via CAN bus – with the ability to diagnose in both alternator and starter modes, as well as read data from the control unit using a diagnostic scanner.\u003cbr\u003e• Starters up to 11 kW (12 V and 24 V) in no-load mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvantages and features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOscillograms of measured parameters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– real-time graphical display of current and voltage.\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTwo testing modes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanual and automatic for alternators and starters.\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAlternator diagnostic reports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– after an automatic test, the test bench generates a report that can be saved and printed. The report form can be customized.\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUser-defined algorithms for alternator autotests\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– the test bench allows using custom algorithms (scripts) for alternator testing.\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAlternator database with connection diagrams\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– speeds up and simplifies diagnostics.\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThermal imaging camera\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– monitoring the unit’s temperature and detecting local overheating.\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12\" touchscreen display\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– convenient and clear control.\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMultilingual interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– user-friendly operation.\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEasy fixation of the unit\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eon the test bench.\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePossibility of using special cables.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThese cables have connectors matching the alternator connector, ensuring quick, correct, and safe connection (purchased separately).\u003cbr\u003e•\u003cspan\u003e \u003cstrong\u003eOptional\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e automatic software updates\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– always up-to-date functionality.\u003c\/p\u003e\n\u003cdiv class=\"name_char_good_group\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv class=\"char_good_list\"\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eSupply voltage, V 400\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003ePower consumption, kW 7.5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eSoftware update optional\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eQuantity of storage batteries\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003e2 by 12V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eBattery model (not included into supply slip)\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eminimum 45 A·h\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eStorage battery charging No.1\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eyes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eStorage battery charging No.2\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eyes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eRated voltage of the diagnosed units, V\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003e12, 24, 48\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eLoad on alternator\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003e12 V - 300 А, 24 V - 150 А, 48 V - 50 А\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eLoad adjustment (0-100%)\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003esmoothly\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eDrive speed, rpm\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003efrom 0 to 3000\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eDrive speed adjustment\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003esmoothly\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eDrive type (unit drive)\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eV-belt drive\/Poly V-belt drive\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eTypes of diagnosed alternators 12V\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eLamp, SIG, RLO, RVC, C KOREA, P-D, G, C JAPAN, COM (LIN, BSS), VALEO «I-StARS»\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eTypes of diagnosed alternators 24V\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eLamp, COM (LIN), PWM, I-ELOOP\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eTypes of diagnosed alternators 48V\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eCAN\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003ePower of diagnosed starters, kW\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eup to 11\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eControl\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eon the 12\" touch screen\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eAutomatic alternator test mode\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eyes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eAlternator database\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eyes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eSaving diagnostic results\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eyes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003ePrinting of diagnostic results\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eavailable on an external printer (not supplied)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eInternet connection\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eWi-Fi (802.11 a\/b\/g\/ac), Ethernet\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eConnection of peripheral devices: 2 x USB 2.0\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eWidth, m0,9\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eDepth, m0,655\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eHeight, m1,43\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eWeight, kg 240\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eSelecting the direction of rotation of the drive\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003eavailable\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eTypes of diagnosed voltage regulators\u003c\/div\u003e\n\u003cdiv class=\"value_char_good_item\"\u003edoesn't test voltage regulator\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eVoltage regulators database: no\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003ePower source: three-phase electrical network\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"char_good_item\"\u003e\n\u003cdiv class=\"name_char_good_item\"\u003eAutomatic starter test mode: yes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MSG","offers":[{"title":"Default Title","offer_id":58334280450422,"sku":null,"price":13490.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1002\/9514\/7894\/files\/1.jpg?v=1784925122","url":"https:\/\/shop.stremtec.nl\/es\/products\/tsh-005a-12-24-48v-testbench","provider":"Stremtec shop","version":"1.0","type":"link"}